USER-SIDE ENERGY STORAGE APPLICATIONS
COMMERCIAL AND INDUSTRIAL GRID-CONNECTED ENERGY STORAGE SOLUTION
Village-level system solution
Some remote and off-grid areas with small populations and far from the main power grid lines usually need to build their own power grids. Using new energy power generation and microgrid technology is a good solution.
Mode 1: Peak shaving and valley filling
Applicable scope:
- Daily electricity load fluctuations are relatively large, such as large shopping malls, office buildings, factories, charging stations, etc.
- Places with large differences between peak and valley electricity prices, and large electricity consumption.
Working mode:
- The energy storage system is connected during the valley period of electricity price to store electricity, and discharged during peak periods of electricity price; to achieve peak load transfer.
Mode 2: Emergency power supply
Applicable scope:
- For different load levels or emergency firefighting power supply (such as finance, securities, shopping malls, factories, etc.)
Working mode:
- When the grid is power cut off, the energy storage system runs off-grid and selectively cuts off secondary loads; ensuring reliable power supply to important loads.
- When there is a grid, the energy storage system runs in parallel to shave peaks and fill valleys.
Mode 3: Smooth load
Applicable scope:
- For intermittent load power consumption such as charging stations, sports centers, etc.
Working mode:
- The energy storage system discharges during peak periods of power consumption to reduce the rate of change in load and achieve the purpose of smoothing the load.
Mode 4: Distribution system expansion
Applicable scope:
- Increased electricity consumption, the original distribution capacity is insufficient.
Working mode:
- When the user needs to increase the power consumption, the original distribution capacity is insufficient. Adding an energy storage system can achieve the expansion effect.
IDC COMMUNICATION ROOM ENERGY STORAGE (240V DC) SYSTEM
Applicable scope:
- IDC communication room, DC power supply system.
Working mode:
- The power supply guarantee in the IDC communication room (240V DC) system is indispensable for the information security system. The IDC communication room energy storage system only needs to add battery capacity on the basis of the original equipment to better guarantee the backup time. Part of the batteries can be used for peak shaving and valley filling to earn price differences.
Customer value:
- More reliable backup power supply
- Improved battery utilization and increased profit points
- N+1 hot backup, high reliability
- Intelligent charge and discharge management
BASED ON UPS ENERGY STORAGE SYSTEM
Applicable scope:
- Emerging UPS users with high demand for power quality and reliability. Such as industrial enterprises, finance, data centers, etc.
Working mode:
- Inverter priority, expand the battery capacity of the UPS system, increase the battery capacity appropriately, part of the capacity is used for backup, and part of the capacity is used for peak shaving and valley filling.
Customer value:
- Both energy storage and backup
- Low investment and high return
- Small amount of retrofit work
- High power quality